Technical Specification
Thermal Insulation
Density Grade
PAC - 4
Mean Compressive Strength (MPa)
2.5
Mean Dry Density (kg/m³)
400-500
Mean Working Density (Kg/m³)
500-600
Dimensional Tolerance (mm)
± 3.0
Dry Thermal Conductivity [w/(m.k)]
≤0.11
Product Dimensions
Thickness
Height
Length
M³
Weight (KG)
100
600
0.036
14.4
150
0.054
21.6
200
0.072
28.8
250
0.09
36
300
0.108
43.2
Thermal Transition
100 mm
150 mm
200 mm
250 mm
300 mm
R-Value
U-Value
0.91
0.93
1.36
0.65
1.82
0.50
2.27
0.41
2.73
0.34
Dry Shrinkage (mm/m)
≤0.20%
Thermal Insulation K Value
0.11 – 0.14
Fire Resistance
Density Class PAC -4
Thickness (mm)
Fire Rating
200 mm and above
4 Hours
Sound Transmission Class (STC)
TC Value (db)
34
39
41
4